Total Hydrocarbon Analyzer RS53-T
Applications
- Emission Monitoring
- Optimizing Processes
- Combustion Control
- Threshold Limit Values (TLV) - Measurements
Features
- Flame Ionization Detector (FID)
- Continuous Measurement Mode
- Dual Channel Analyzer available (RS53-T/2)
- TUV-approved (meets EPA-approval)
- Heated Analytical Compartment (up to 200 °C / 473 K)
- Auto Ignition
- Flame-Out Indication
- Automatic Hydrogen Cut-Off
- Self-Monitoring Capabilities
- Electronic SAmple Pressure Regulator
- Auto / Manual Range
- Zero and Calibration over Sample Line
- Internal Zero-Gas and Combustion-Air Generator
- Integrated Sample Filter
- Integrated Fuel Gas Cylinder
- Integrated Calibration Gas Cylinder
- Hydrogen / Helium-Hydrogen Fuel Selector
- Easy Handling
- Portable (approx. 20 kg)
- Option: ppb-Measurement Ranges
- Option: Sample Lines
- Option: External Filters
- Option: USB-Interface
- Option: Filling Adaptors
Specifications
(Reference Quantity: Full Range Deflection = FRD)
5 Measurement Ranges |
|
Linearity | +/- 2 % MBE (up to Range 4) |
Oxygen Cross Sensitivity | < +/- 2 % FRD (with He/H2 Fuel) |
Limit of Detection | < 2 % FRD |
Zero Driftt | < 2 % FRD/week |
Span Drift | < 4 % FRD/week |
Response Time90 | approx. 1-2 s |
Sample Flow Rate | approx. 90 l/h |
Analytical Temperature | up to 200°C |
Signal Output | 0-10 V and/or 0/4-20 mA |
Status Contacts |
|
Dimensions | 360 x 200 x 500 mm (WxHxD) |
Weight | approx. 20 kg |
Ambient Temperature | +5 ... +35 °C |
Main Power | 230 V / 50 Hz or 115 V / 60(50) Hz / 450 Watts |