Your Reliable Partner for THC Measurements

Total Hydrocarbon Analyzer RS55-T/2

Applications

  • Measurements at two Sample Points
  • Emission Monitoring
  • Optimizing Processes
  • Combustion Control
  • Threshold Limit Values (TLV) - Measurements
Total Hydrocarbon Analyzer RS55-T/2

Features

  • Heated Analytical Compartment (up to 160 °C / 320 °F)
  • 2 Sample Inputs, Manual or Auto-Control
  • Continuous  / Discontinuous Measurement Mode
  • Flame Out Indication
  • Auto-Range / Manual Range
  • Automatic Hydrogen Cut-Off
  • Self-Monitoring Capabilities (Temperatures, Pressures, Flame)
  • Option: Sample Lines
  • Option: Filters
  • Option: Internal Zero-Gas and Combustion-Air Supply
  • Option: USB-Interface
Total Hydrocarbon Analyzer RS55-T/2 Back

Specifications

(Reference Quantity : Full Range Deflection = FRD)

Ranges
  • 0-10 ppm Propane
  • 0-100 ppm Propane
  • 0-1.000 ppm Propane
  • 0-10.000 ppm Propane
  • 0-100.000 ppm Propane

Linearity

Sample Input Select

+/- 2 % FRD (up to Range 4)

Manual or Automatic, Time Base 1-99 Minutes 

Oxygen Cross Sensitivity < +/- 2 % FRD
Availability

> 95 %

Limit of Detection < 2 % FRD
Zero Drift < 2 % FRD/week
Span Drift < 4 % FRD/week
Response Time approx. 1-2 s (without sample line)
Sample Flow Rate approx. 220 l/h
Signal Output 0-10 V or 0/4-20 mA
Status Contacts
  • Pre (Concentration-) Alarm
  • Main (Concentration-) Alarm
  • Range Identification
  • Flame Out Indication
  • Status Identification (Zero-Gas/Span- Gas/Calibration)
  • Alarms (Pressure, Temperature, Flame)
Dimensions 19" x 267 x 500 mm (WxHxD)
Weight approx. 26,5 kg
Ambient Temperature + 5 ... + 35 °C
Main Power

230 V / 50 Hz or 115 V / 60(50) Hz / 800 Watts